- The V200 input monitor interface connects up to 16 supervised input circuits. Each input point monitors and reports normal, off-normal, and alarm states.
- The V200 features on-board flash memory, allowing program updates to be downloaded through the network. The V200 connects to the V1000 via a high speed RS-485 network.
- The V1000, in turn, communicates with the system host via industry standard TCP/IP protocol, over 10/100 Mbps Ethernet, or the Internet. This architecture minimizes the impact on corporate LANs, by using only one TCP/IP address for every 32 interfaces, and by handling low-level transactions on the RS-485 network.
- The HID VertX products provide a complete and fully featured hardware/firmware infrastructure for access control software host systems.
Key Benefits
- Reports supervised or un-supervised alarm circuits.
- Off-normal condition programmable for each input point (NO or NC alarm devices may be used).
- Connects to the V1000 via RS-485.
- Receives and processes real time commands from the V1000.
- Reports all activity to the V1000.
- Allows complex input/output linking when used with the V1000 and V300 Output Control Interface.
- Attractive polycarbonate enclosure protects components from damage.
- All connections and indicators are fully identified by silk-screened nomenclatureon the cover.
- UL 294 and UL 1076 recognized components.
Dimensions |
5.8" W x 4.825" H x 1.275" D (147.32 mm x 122.55 mm x 32.38 mm) |
Weight |
12.4 oz (.35 kg) |
Power Supply Requirements |
50 mA @ 9-18 VDCRecommended: Supervised linear power supply with battery back-up, input surge protection, and AC fail and battery low contact outputs. Separate supervised DC supply with battery back-up recommended for relay activated devices. |
Communication |
- RS-485 - 4000 feet (1220 m) to host, using Belden 3105A,22AWG twisted pair, shielded 100? cable Input Circuits - 500 feet (150 m), two-conductor, shielded,using ALPHA 1292C (22AWG) or Alpha 2421C (18AWG). - Output Circuits - 500 feet (150 m), 2-conductor, using ALPHA. 1172C (22AWG) or Alpha 1897C (18AWG). Minimum wire gauge depends on cable length and current requirements. |
Operating Environment |
32 ° đến 122 ° F (0 ° đến 50 ° C) |
Certificate |
UL 294 and UL 1076 Recognized Component for the US CSA 205 for Canada FCC Class A Verification EMC for Canada, EU (CE Mark), Australia (C-Tick Mark), New Zealand, Japan EN 50130-4 Access Control Systems Immunity for the EU (CE Mark) |